Jamestown temperature snap disc replacement for 07FDE & 07FDB - 80P20038-R F110

Jamestown temperature snap disc replacement for 80P20038-R F110

The 07FDE keeps the power to the auger motor when the stove enters the run cycle. The 07FDB turns the convection fan or room heat blower on when the exhaust temperature is 130 Degs. Replacement with the above F-110 replacement snap disc will turn the fan on sooner for more efficiency

Note: These switches operate properly when there is good metal to metal contact qith the stove. So be sure to wire wheel the metal area under the switch and assure the bolts are tighened properly and are not stripped or loose